PRODUKT APLIKACE
• Used for cable fire prevention, to strengthen the fireproof performance of cable sheath;
• Suitable for additional insulation and cable parts prone to failure where there are fire hazards;
• Suitable for high and low-voltage power supply lines, especially fire retardant engineering of cables laid under environmental conditions such as channel, tunnel, and overhead in power plants, substations, iron and steel, chemical industry, construction, subways, mines, and ships;
• Applicable to all forms of fire spreading, effectively isolating fire spreading.
PRODUKT Technické ukazatele
SPECIFIKACE: X-FHD-108 |
|||
VLASTNICTVÍ |
HODNOTA |
JEDNOTKA |
TEST METODA |
Fyzický vlastnictví |
|||
Pevnost v tahu | ≥3 | MPa | GB/T 528-2009 |
Prodloužení po přetržení | ≥500 | MPa | GB/T 528-2009 |
Rychlost změny pevnosti v tahu | ≤±20% | --- | GB/T2951.12-2008 |
Změna rychlosti prodloužení při přetržení | ≤±20% | --- | GB/T 2951.12-2008 |
Voděodolnost | Ponoření na 15 dní, žádné bubliny, vrásčitá delaminace, praskání a další jevy | — | Ga478-2004 |
Odolnost vůči kyselinám, odolnost vůči alkáliím, odolnost vůči soli | Ponoření na 7 dní, žádné bubliny, zvrásnění, delaminace, praskání a další jevy | — | Ga478-2004 |
Vlastní viskozita | Žádné uvolnění po dobu 24 hodin | — | Ga478-2004 |
Index kyslíku |
≥32 |
% | GB/T 2046.2-2009 |
Třída zpomalující hoření | V-0 | — | UL94-2015 |
Obsah halogenu |
Obsah bromu a chloru je nižší než 900 ppm. Celkový obsah bromu + chloru je menší než 1500 ppm |
— | EN14582:2016 |
Stupeň hustoty kouře | ≤15 | — | GB/T 8627-2007 |
Údaje v tabulce představují průměrné výsledky testů a nesmějí být použity pro účely specifikace. Uživatel produktu by měl provést své vlastní testy, aby určil produkt. Je vhodný pro zamýšlené použití. |
PRODUKT Obecné Specifikace
STANDARDNÍ VELIKOSTI: | ||
Šířka |
Délka |
Tloušťka |
60 mm |
5 m | 0,7 mm |
K dispozici jsou jiné velikosti a jádra. Kontaktujte továrnu |