PRODUCT APPLICATION
Used with heat-shrinkable and cold-shrinkable materials, used in 1-35kv cross-linked cable terminal and intermediate connector, for filling, insulation, waterproof, and sealing; Used for the modification of distribution network, the connection of overhead insulated wire and the filling waterproof of branch wire clip; Used for filling and waterproofing the end and joint of communication cable; Used for filling waterproof of communication base station, antenna, etc.
PRODUCT Technical indicators
SPECIFICATIONS: XF-SFS(20-70/PC) |
|||
PROPERTY |
VALUE |
UNIT |
TEST METHOD |
Physical property |
|||
Thickness | 2 | mm | GB/T533-2008 |
Breaking strength | ≥200 | MPa | GB/T533-2008 |
Elongation at break | ≥500 | --- | GB/T328.9-2007 |
Dielectric Strength | ≥18 | kV/mm | JC/T942-2004 |
Volume Resistivity | ≥1x10 | Ω·cm | JC/T942-2004 |
Dielectric Constant | ≤3.5 | --- | JC/T942-2004 |
Heat-raslsiant strass cracking |
130℃,1h No cracking, no dripping |
--- | JC/T942-2004 |
Heat Resistance | --- | --- | JC/T942-2004 |
Peeling strength | --- | --- | JC/T942-2004 |
Peeling strength of steel plate | ≥10 | N/25mm | JC/T942-2004 |
Yeah, polyethylene plate. Pecling strength |
≥12 | N/25mm | JC/T942-2004 |
Data in the table represent average test results and are not to be used for specification purposes. The product user should make his l her own tests to determine the product.it's suitable for the intended use. |
PRODUCT General specifications
STANDARD SIZES: | ||
Width |
Length |
Thickness |
26mm |
330m | 2mm |
Other sizes and cores are available. Contact factory |
PRODUCT DISPLAY